<LOGO>
FM Transmitter Measurement Report
Created: 2026-09-02 13-43-53
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 52 dBuV Classic
Pilot RDS Phase Difference
6.9 kHz 3.1 kHz -45 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 64 kHz 18922 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-0,3 dBr 1,21 dBr 4,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Requiem: "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 64 kHz MIN: 10 kHz % above 76 kHz: 0,0000 Acquired: 2026.09.02 13.42.49 Total samples: 18922 Equivalent time: 0:15:46 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 4,1 dBr MIN: -0,3 dBr AVE: 1,21 dBr % above 12,2 dBr: 0,0 Last value: 2,6 dBr (2026.09.02 13.42.49) 13.28 13.30 13.32 13.34 13.36 13.38 13.40 13.42 0 2 4 Pm [dBr]